Add to Cart
Environmental Data
INC-x-58 | ||
Operating Temp. | Minus 45 to +85 Minus 60 to +85Celsius for 12VCT & 24VCT Product Option. Minus45 to +105Celsius max . for 5HT Product Option Operation outside limits to be qualified by user . | Celsius |
Storage Temp. | Minus 55 to +125 (Minus 60 to +125 for 24CT Product Option) | Celsius |
Temperature Shock | MIL-STD-810G, Method 503.5, Procedure I-B (T1=-40 oC, T2=55 oC .) | |
IP Rating - Rotor & Stator | IP67 for <60 minutes & 1m depth (Installed with mechanically protected connector or AFL1-5 or VFL1-5 Product Options) For additional protection for long term immersion at depth, specify product option AFL2-52 or VFL2-52 Product Option For immersion at depths of >100m select Extended Range High Pressure Option | |
IP Rating - Connector | IP50 (ACx or RCx Product Option) . See Section 4.7 for IP rating of AFLx & VFLx Product Option | |
Humidity | RH 0-99% standard. Select Extended Range Option C & appropriate connector for condensing humidity or long term immersion | |
Salt Fog | (Installed with protected cable/connector or any integral axial cable) Complies with DEF STAN 00-35 Pt. 3 Iss. 4, Test CN2 Salt Mist Test. Select Extended Range Option C and appropriate connector for environments with significant exposure to salt fog | |
Bio Hazards | (Installed with protected cable/connector or any integral axial cable) Complies with DEF-STAN 00-35 Pt. 4 Iss. 4 Section 11 (Hazards) | |
Induced Dust & Sand | Complies with DEF STAN 00-35 Pt 3 Iss 4, Test CL25 (Turbulent Dust) Cat 1. Select Extended Range Option C and appropriate connector for environments with abrasive dust or sand. | |
Mechanical Impact Resistance | IK07 - when installed - suitable for mechanical impacts from objects of >200grams from 1m height | |
Shock | IEC 60068-2-27 100g for 11ms - axial & radial - suitable for most airborne, marine & armoured vehicles MIL-STD-810G, Method 516.6, Procedure I- Functional Shock - axial and radial - 40 g 11 ms, sawtooth waveform For more extreme or prolonged conditions specify Extended Product Option G & preferably Integral Axial Cable | |
Vibration | IEC 60068-2-6 20g for 10-2000Hz - axial and radial - suitable for most high vibration & airborne environments MIL-STD-810G, Method 514.6, Procedure I - axial and radial - Category 20, for tracked vehicles For more extreme or prolonged conditions specify Extended Product Option G and preferably Integral Axial Cable | |
Environmental pressure range | 0 to 7 (i.e. vacuum to 7). See Extended Product Range High Pressure Option for higher operating pressures | Bar |
Max. permissible press. change rate | 1 | Bar/second |
EMC Radiated Susceptibility | (Installed) Complies with IEC 61000-6-2 - suitable for fitment in harsh EMC environments | |
EMC Radiated Emissions | (Installed) Complies with IEC 61000-6-4 - suitable for fitment adjacent to EMI sensitive devices | |
Materials - all Product Options | ||
Rotor & Stator Housings | Standard range:- Al. alloy (6061-T6 or 6084-T6) with SurTec650. Sensor surfaces: FR4 grade epoxy Product Option A or S:- Alocrom finish al. alloy (6061-T6 or 6084-T6) . Sensor surfaces: FR4 grade epoxy | |
Connector (ACx or RCx Product Option) | PPS with Stainless Steel Screw Fixings and Gold & Tin Electrical Connections | |
Miscellaneous - all Product Options | ||
Mass Shaft Clamp Rotor (max.) | 43 | grams |
Mass Plain Rotor (max.) | 32 | grams |
Mass Servo Clamp Stator (AC1 ) | 43 | grams |
Mom. of Inertia Shaft Clamp Rotor (max.) | 2.0E-05 | Kgm2 |
Mom. of Inertia Plain Rotor (max.) | 1.8E-05 | Kgm2 |
MTBF | 0.22 failures per 1M hours based on MIL- HBK-217+ method for ground military vehicles at 20Celsius average | |
MTBF | 0.35 failures per 1M hours based on MIL- HBK-217+ method for naval sheltered at 35Celsius average | |
Hazardous materials | Standard range - Hazardous materials not used. RoHS compliant. RoHS certificate available. REACH statement available. | |
Outgassing materials | Complies with NASA class'n as low outgas matl. with TML <1% & CVCM <0.1% at 125C & 24hrs vacuum to ASTM E-595-90 | |
ITAR classification | Not ITAR controlled. No ITAR components | |
Approvals | Flammability Rating UL94V-0. Standard range - RoHS compliant - RoHS certificate available. REACH statement available. | |
Marking | Zettlex, logo, CE & UL94V-0 printed on Rotor & Stator faces; Serial No. labelled on exterior diameter of Stator housing Extended Product Range Option E - engraved serial number and part number on exterior faces of Stator & Rotor | |
Country of Manufacture | UK | |
Export Licence Requirements | Not required for standard product options |
Applications – Camera Gimbals